Structural reinforcement at the Scanner Diagnostic Centre
Process:
- Demolition of the concrete that has come loose from the beams and subsequent washing with pressurised water.
- Restructuring of the concrete with Sika Systems. Consisting of: Sika monotop 910 as an anti-corrosion system for iron reinforcement and a bridge between old and new concrete repair + Application of structural mortar R4 Sika monotop 412 S.
- Structural reinforcement of the beams with Sika Carbodur carbon fibre sheets bonded with Sikadur 30 epoxy resin